sales@wireharnessworks.com +86 19574989725 Shenzhen, Tiongkok www.wireharnessworks.com
WC-03 · Kawat dan Kabel

Kabel Adaptor Komunikasi Multi-Peralatan — Rangkaian Kabel Berpelindung Las Tembaga Jantan / Betina Cross-Pinout D-Sub

Kabel adaptor kustom yang menjembatani pinout, gender, dan protokol konektor yang berbeda di seluruh peralatan multi-vendor. Pengubah gender D-Sub ↔ D-Sub, konverter cross-pinout DB9 ↔ DB15 ↔ DB25, jembatan protokol RS-232 ↔ RS-485 / RS-422, dan referensi silang P/N lama (B5 MFC, P5 CONT, seri 0150). UL2464 berpelindung, terminal las tembaga berlapis emas. Pinout kustom per drawing.

FunctionCross-pinout · Gender change
Cable StyleUL2464 shielded multi-core
ConnectorsD-Sub DB9 / 15 / 25 / 37
TerminationCopper welded · gold-plated
Aplikasi
Stasiun tes multi-vendor, jembatan peralatan lama-ke-modern, integrasi semikonduktor / finansial / medis / CNC
Tipe Adaptor
Pengubah gender · Cross-pinout · Null modem · Jembatan protokol
Jumlah Pin D-Sub
DB9 / DB15 / DB25 / DB37 / DB50 + HD15 / HD26 / HD44 / HD62
Protokol yang Didukung
RS-232 · RS-485 · RS-422 (crossover pasif atau konverter aktif)
Gaya Kabel
UL2464 berpelindung · 5×24AWG atau 8×24AWG (kustom 2-25 inti)
Referensi Silang P/N
Seri B5 MFC · P5 CONT · 0150-10049 · 0150-1044 · 0150-10074
Terminasi
Kupa solder las tembaga · berlapis emas · kabang kunci sekrup jempol

FACTORY DIRECT · OEM/ODM welcome · 100% pull tested · 1500 VAC withstand check · IATF 16949 quality system

Product Overview

Deskripsi

Kabel Adaptor Komunikasi Multi-Peralatan memecahkan sakit kepala integrasi sehari-hari yang dihadapi oleh setiap insinyur tes, integrator otomasi, dan teknisi servis lapangan: dua perangkat yang harus berkomunikasi tetapi memiliki konektor yang tidak kompatibel, gender yang salah, atau pinout yang berbeda. Kabel ini adalah konverter yang dibangun khusus yang menjembatani perbedaan-perbedaan tersebut — sering kali dengan pemetaan pin yang dikustomisasi, konversi protokol, atau referensi silang nomor bagian lama yang dibangun ke dalam satu kabel.

Empat kelas adaptor dikirim dari lini produk ini. Pengubah gender menukar M-M menjadi F-F atau sebaliknya dalam keluarga D-Sub yang sama — memecahkan masalah klasik "dua jantan saling berhadapan". Konverter cross-pinout mengkabel ulang DB9 ↔ DB15 ↔ DB25 ↔ DB37 sesuai gambar — pinout kustom Anda, eksekusi las-solder kami. Jembatan protokol menerjemahkan antara standar RS-232, RS-485, dan RS-422 baik secara pasif (null-modem) atau aktif (transceiver inline). Adaptor referensi silang P/N lama membangun ulang kabel kepemilikan dari sampel atau nomor bagian dari basis data internal kami.

Kami merujuk silang dan membangun nomor bagian lama dalam seri B5 MFC, P5 CONT, 0150-10049, 0150-1044, dan 0150-10074 — kabel yang Anda temukan berlabel di belakang instrumen Tektronix lama, modul finansial DEC, atau peralatan kontrol industri tahun 1990-an yang masih menjalankan dunia. UL2464 berpelindung, terminal D-Sub las tembaga berlapis emas, semua pengkabelan diverifikasi ujung-ke-ujung dengan IR ≥ 100 MΩ, hi-pot 500 VAC, dan kontinuitas pelindung diuji.

Key Features

Mengapa Rangkaian Kabel Ini

01

Pembuatan Pengubah Gender

Adaptor M-M dan F-F dalam keluarga D-Sub yang sama — memecahkan masalah integrasi "dua jantan saling berhadapan".

02

Konversi Cross-Pinout

Pengkabelan silang DB9 ↔ DB15 ↔ DB25 ↔ DB37 sesuai gambar — pinout kustom Anda, eksekusi las-solder kami.

03

Jembatan RS-232 / RS-485 / RS-422

Null-modem pasif atau transceiver inline aktif — terjemahkan antara standar protokol serial dalam satu kabel.

04

Referensi Silang P/N Lama

Seri B5 MFC, P5 CONT, 0150-10049 / 0150-1044 / 0150-10074 — kirim sampel, kami merujuk silang dan membangun ulang.

05

UL2464 + D-Sub Berlapis Emas

Konstruksi kabel berpelindung UL2464 dengan pelindung EMI foil + kepang. Terminal D-Sub las tembaga berlapis emas.

06

100% Peta Pin Diverifikasi

Setiap konduktor diverifikasi ujung-ke-ujung dengan pemetaan cross-pin yang benar. IR ≥ 100 MΩ, hi-pot 500 VAC, kontinuitas pelindung diuji.

Technical Data

Spesifikasi

Product CodeWC-03 · WHW-MULTI-EQUIP-ADAPTER
Seri ProdukMulti-Equipment Adapter Cable — D-Sub Cross-Pinout Family
Application FieldMulti-vendor test stations, legacy-to-modern bridges, equipment integration
Cable StyleUL2464 (UL recognized internal wiring · 300V · 80 °C · VW-1)
Conductor Options5×24AWG (5×0.3 mm²) · 8×24AWG (8×0.3 mm²) · custom 2-25 cores
ConductorTinned copper, stranded
IsolasiPVC, multi-color UL standard code
Outer JacketPVC, gray (standard) · black on request
ShieldingAluminum-foil + tinned-copper braid + drain wire
D-Sub Pin CountsDB9 / DB15 / DB25 / DB37 / DB50 + HD15 / HD26 / HD44 / HD62
D-Sub GenderMale ↔ Male · Male ↔ Female · Female ↔ Female
D-Sub PlatingGold-plated contacts (standard)
D-Sub ShellBlack plastic with metal EMI teeth · thumbscrew / jackscrew lock
TerminationCopper welded (solder cup) — IPC/WHMA-A-620 pull-tested
Cable LabelsP1 / J100 / J1 / B5 MFC / P5 CONT and OEM ID per drawing
P/N Cross-Reference0150-10049 · 0150-1044 · 0150-10074 · B5 MFC · P5 CONT
Protocols SupportedRS-232 (passive) · RS-232 ↔ RS-485 (active) · RS-232 ↔ RS-422 (active)
Variant AGender changer — D-Sub M-M / F-F same family
Variant BCross-pinout converter — DB9 ↔ DB15 / DB25 etc.
Variant CNull-modem / crossover — TX/RX swap, CTS/RTS rewired
Variant DActive protocol bridge — inline RS-232/485/422 transceiver module
Withstand Voltage500 VAC / 60 s hi-pot
Insulation Resistance≥ 100 MΩ at 500 VDC
Pin-Map Verification100% per-conductor continuity with cross-pin verification
Custom Length100 mm to 30 m (RS-232) · up to 1200 m (RS-485 active)
SertifikasiUL2464 wire · RoHS · REACH
Quality SystemIATF 16949 · ISO 9001 · IPC/WHMA-A-620
Packing Dimensions30 × 20 × 15 cm · ~1 g/cm length
MOQ10 pcs (prototype-friendly)
Waktu Tunggu Sampel7–10 days
Mass Production Lead Time15–25 days after artwork approval
FAQ

Pertanyaan yang Sering Diajukan

What is the difference between a straight-through cable and an adapter cable?
A straight-through cable carries every conductor from pin N on one end to pin N on the other end — same connector type, same gender, same pinout. An adapter cable changes one or more of these dimensions: gender (M-M or F-F gender changer), connector type (DB9 to DB15 converter), pinout (RS-232 crossover, null-modem), or even protocol (RS-232 to RS-485 with active translator chip). Adapter cables are essential when bridging legacy and modern equipment, mixing different vendors' instruments in one test station, or matching a host PC to a non-standard piece of laboratory or production hardware.
Which D-Sub adapter combinations can you build?
Any combination on request. Common builds: DB9 ↔ DB9 (gender change or crossover), DB9 ↔ DB15, DB9 ↔ DB25, DB15 ↔ DB25, DB15 ↔ DB37, DB25 ↔ DB37, and high-density variants HD15, HD26, HD44, HD62 in either direction. Gold-plated contacts, copper-welded (solder-cup) joints, metal shells with EMI-grounding teeth, and thumbscrew or jackscrew locks are standard on every build. Each conductor cross-routes per your pinout drawing.
Do you handle RS-232 to RS-485 / RS-422 protocol conversion?
Yes — we build both passive crossover cables (null-modem RS-232 with TX/RX swapped, CTS/RTS handshake re-wired) and active converter cables that include an inline molded module with an RS-232 / RS-485 / RS-422 transceiver chip. The active versions are powered from the host port or a USB pigtail. Cable length up to 30 m for RS-232, much longer for RS-485 / RS-422 builds. Custom pinouts welcome — send schematic or sample, we quote within 24 hours.
Which equipment is this adapter cable designed for?
The adapter cable family is built for multi-equipment integration challenges: legacy instrument (DB9 RS-232) to modern PC (USB / DB25), older PLC to new HMI, multi-vendor test station bench where each instrument has its own connector convention, semiconductor fab equipment with non-standard 0150-series Tektronix-style cables, financial machines, medical analyzers, CNC controllers, and industrial automation cabinets. Reference part numbers we handle include B5 MFC, P5 CONT, 0150-10049, 0150-1044, 0150-10074 and the full 0150-series. If you have a legacy P/N, send it — we cross-reference and quote.
What testing and quality checks are performed?
100% continuity test per conductor — every wire is verified end-to-end with the correct cross-pin mapping. Insulation resistance test (≥ 100 MΩ at 500 VDC), pin-to-shell isolation test, and a 500 VAC / 60-second hi-pot withstand check. Shielding continuity verified end-to-end with a milliohm meter. Soldered D-Sub joints are pull-tested per IPC/WHMA-A-620. Drawings are stamped, every cable serialized. RoHS and REACH compliant. SGS pre-shipment inspection on request.
Applications

Di Mana Dipasang

01

Stasiun tes multi-vendor

02

Jembatan instrumen lama

03

Peralatan fab semikonduktor

04

Modul mesin finansial

05

Integrasi penganalisis medis

06

Peningkatan pengendali CNC

07

Jembatan RS-232 / 485 / 422

08

Kabinet otomasi industri

Related Products

Pelanggan Juga Melihat

Need a custom adapter cable to bridge two devices?

Send us the source and target connector P/N, pinout drawing, or sample of the original cable — we cross-reference legacy 0150-series, B5 MFC, P5 CONT, build gender changers, cross-pinout converters, RS-232/485/422 bridges. MOQ from 10 pcs. We'll quote within 24 hours and ship a working sample in 7–10 days.

📧 Dapatkan Penawaran — sales@wireharnessworks.com